PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
PVC Coated Fabric for Firewood Roof Camping – Technical Grade
Certified: ISO9001 ISO14001 ISO45001 CE

PVC Coated Fabric for Firewood Roof Camping – Technical Grade

PVC Coated Heavy-Duty Tarpaulin — 250gsm-1500gsm, 200DX300D to 1000DX1000D base fabric, glossy or matte finish with waterproof, UV and flame-retardant treatment applied during coating.

Coating weight and base denier together determine tensile and tear performance; selecting the right GSM-to-denier ratio matters more than maximum weight alone. Surface finish affects weld behaviour during fabrication.

  • Supported by dedicated QA/QC with 100% pre-shipment inspection on every roll
  • Specification sheet, test reports and customs documentation provided with each dispatch

OEM / ODM

✓ Supported

Supply

Factory Direct

Experience

30+ Years

Export

20+ Countries

ISO & CE Certified
Fast Sample Turnaround
Ships to 20+ Countries
Full OEM / ODM Support

Deep Coating Adhesion Control — every roll of this PVC coated fabric is produced with monitored coating weight and base fabric adhesion to meet the demanding flex and pressure cycles found in ventilation duct and inflatable structure service.

Technical Specifications

Parameter Value
Product Type PVC Coated Tarpaulin
Base Fabric Denier 200D×300D / 500D×500D / 840D×840D / 1000D×1000D
Weight (GSM) 250gsm–1500gsm (range covers product family — confirm the grade for this item)
Total Thickness 13mil
Available Sizes 20×30 Feet, 3×4m, 6×8m, 8×10m, 10×12m or custom made
Surface Finish Glossy or matte
Available Colours Blue, yellow, black, green, white, and others on request
Treatment Options Waterproof, UV, flame retardant (grade not stated in source — confirm required grade), anti-fungal
Temperature Range -15°C to 70°C
Environment Eco-friendly formulation
OEM / ODM Accepted

Application Suitability

Application Exposure & Requirement
Mine and tunnelling ventilation ducts Continuous airflow pressure cycling, underground moisture, mandatory fire-retardant compliance
Aviation ground support ducting Fuel vapour proximity, rapid deployment and teardown, surface abrasion on tarmac
Inflatable and membrane structures Biaxial tension, solar UV load, weld seam integrity under internal pressure
Temporary site enclosures Wind-driven rain, mechanical contact with scaffolding and plant equipment
Specialist shelters and covers Wide temperature swings, long-term weather exposure, chemical contact risk

Why Fire-Retardant Documentation Matters More Than the Label

A PVC coated fabric marked "flame retardant" without a named test standard leaves the site safety officer guessing. Certification is only as useful as the test report that backs it. Mining and tunnelling contractors regularly face project audits where the duct fabric must match a specific fire classification — M2, B1, NFPA 701, or DIN 4102 — and a generic claim does not satisfy the inspector [NEED_CITE: fire classification standards applicable to ventilation duct fabrics in underground mining]. When the documentation gap surfaces during a site inspection, the entire duct run can be rejected, forcing a costly replacement mid-project.

Base Fabric Denier and Structural Integrity in Duct Applications

The base fabric denier directly governs how well the material resists tearing under the constant flex and pressure pulsation of forced ventilation. Options from 200D×300D up to 1000D×1000D allow the PVC coated fabric to be matched to the duct diameter and static pressure of the system. Higher denier constructions hold welded seams under sustained internal pressure without delamination at the coating-to-yarn interface.

Flame Retardant and Anti-Fungal Treatment Verification

Flame retardant treatment is available across the range, though the specific grade must be confirmed against your project specification. Anti-fungal treatment addresses the moisture-saturated environments typical of underground ventilation, where biological growth on the fabric surface can degrade coating adhesion over time. Each treatment should be supported by a test report stating the method and classification achieved [NEED_CITE: anti-fungal and flame retardant test methods for coated technical textiles].

Coating Weight, Denier, and Temperature Boundaries

Total thickness of 13mil combined with the selected denier determines how the fabric handles biaxial tension in inflatable and membrane applications. The operating window of -15°C to 70°C covers most surface and underground ventilation environments, but low-temperature handling requires care — below the lower limit, PVC stiffens and the risk of crease-whitening increases during unrolling. Coating weight, stated in GSM, must be read alongside denier: a lighter denier with a heavier coat may offer surface durability but will not match the tear propagation resistance of a heavier base yarn. Surface finish — glossy or matte — also influences weld behaviour; matte surfaces typically require adjusted heat settings during high-frequency or hot-air welding to achieve consistent peel strength.

PVC coated fabric weave and coating cross-section for ventilation duct applications

When the Wrong Specification Reaches Site

Selecting a denier too light for the duct diameter results in seam failure at the flex points where the fabric experiences repeated pressure cycling. If the fire-retardant grade does not match the project specification, the ventilation system may fail the compliance inspection, halting underground operations until replacement material arrives [NEED_CITE: consequences of non-compliant ventilation fabric in mining operations]. Colour inconsistency between rolls used on the same inflatable structure creates visible panel mismatch once inflated and viewed in direct sunlight.

How Production Control Supports Technical Compliance

Three full production lines allow dedicated scheduling for fire-retardant and anti-static grades, reducing the risk of cross-contamination between standard and treated batches. The ten-person R&D team develops samples against your exact denier, GSM, and treatment requirement before bulk commitment. In-process QA checks coating weight at intervals during each production run rather than only at final inspection. Every roll undergoes a full pre-shipment check against the material specification sheet before packing, catching GSM deviation and surface defects before they reach the port.

Documentation & Verification

  • Material specification sheet confirming denier, coating weight, and GSM for the exact grade shipped
  • Fire-retardant test report matched to M2, B1, NFPA 701, or DIN 4102 as applicable
  • Anti-static surface resistance result where underground or explosive atmosphere compliance is required
  • Pre-shipment inspection record covering weight, colour, and coating adhesion per roll
  • Certificate of origin and customs documentation included with every export shipment

Fabrication, Handling & Storage

  • Adjust hot-air weld temperature to surface finish; matte PVC coated fabric typically needs higher dwell time for full peel strength
  • Allow rolls to acclimatise above 10°C before unrolling to prevent crease-whitening in the 13mil construction
  • Store rolls horizontally on racking to avoid compression marks on the coating surface
  • Use compatible PVC-based repair adhesive for field patching; solvent-based contact cement may attack the coating layer
  • Plan cut patterns to minimise transverse seams in duct sections, aligning welds with the fabric machine direction
  • Clean with mild detergent only; aggressive solvents degrade the anti-fungal surface treatment

What to Include in Your Enquiry

To move quickly from enquiry to sample, specify the fire-retardant or anti-static classification your project demands, the duct diameter or structure dimensions you are fabricating toward, and the denier and GSM range you are evaluating. Confirm whether you need roll stock for in-house fabrication or finished panels with welded seams, and state any colour or surface finish preference so that a representative sample can be prepared.

Frequently Asked Questions

Q: Which fire-retardant grade should I specify for underground mining ventilation ducts?
A: The required grade depends on the jurisdiction and the mining authority overseeing the project. Common classifications include M2, B1, NFPA 701, and DIN 4102. Share the specific standard your site safety plan references, and a matching test report can be prepared for the selected PVC coated fabric grade before production begins.

Q: How is anti-static performance measured and what range is achievable?
A: Anti-static performance is assessed by surface resistance testing, with results reported in ohms. Underground and explosive atmosphere projects typically require a surface resistance within a defined range stated in the project specification. Confirm the target value early so the formulation can be adjusted during the coating stage.

Q: Can welded seams in this fabric maintain the fire-retardant rating?
A: Welded seams can maintain the rating provided the welding process does not burn off the treatment at the seam line. Hot-air and high-frequency welding are preferred over open-flame methods. Request a seam sample with the fire-retardant grade you need so weld parameters can be validated before full production.

Q: What denier and GSM combination suits inflatable membrane structures?
A: Inflatable structures subject to continuous biaxial tension generally benefit from higher denier base fabrics such as 840D×840D or 1000D×1000D paired with a mid-to-heavy GSM grade. The exact selection depends on the internal pressure, span, and expected wind load. Provide your engineering parameters for a targeted recommendation.

Q: What compliance documents ship with each order?
A: Each shipment includes a material specification sheet, fire-retardant test report where applicable, anti-static test result if specified, pre-shipment inspection record, certificate of origin, and packing list. ISO and CE certificates are available to support site inspections and customs clearance at destination.

Get a Free Quote

Ready to Discuss Your Requirements?

Tell us your specifications, quantity, and application. Our team will respond within 24 hours with a tailored quote and sample options.

Email

tarp@jxtarp.com

Phone / WhatsApp

+86 137 9310 1270

Address

No. 319, Jiqi Road, Huaiyin District,
Jinan City, Shandong, China

How It Works

  1. 1 Consultation -- Share your specs & quantity
  2. 2 Sample -- We prepare & ship a custom sample
  3. 3 Quote -- Formal quotation & contract
  4. 4 Production -- Full-process QA inspection
  5. 5 Delivery -- Goods shipped, balance settled

Send Your Inquiry

By submitting, you agree to be contacted regarding your inquiry. We respect your privacy.

Related Products

You may also be interested in these products

View All

Need a Custom Solution for This Product?

Our team is ready to provide OEM/ODM customization, competitive pricing, and fast sample turnaround. Let's build a long-term partnership.